Compartilhar
Informação da revista
Vol. 94. Núm. 3.
Páginas 366-368 (1 maio 2019)
Compartilhar
Compartilhar
Baixar PDF
Mais opções do artigo
Vol. 94. Núm. 3.
Páginas 366-368 (1 maio 2019)
Open Access
The diagnosis of cosmetic contact dermatitis: a study using standard, cosmetic, and hair cosmetic batteries*
Visitas
4389
Mariele Bevilaqua1, Michelle Bortolotto Cichelero2, Rebeca Kollar Vieira da Silva2, Renan Rangel Bonamigo1,3
1 Postgraduate program in Pathology, Universidade Federal de Ciências da Saúde de Porto Alegre, Porto Alegre (RS), Brazil.
2 Medicine Department, Universidade Federal de Ciências da Saúde de Porto Alegre, Porto Alegre (RS), Brazil.
3 Service of Dermatology, Hospital de Clínicas de Porto Alegre, Universidade Federal do Rio Grande do Sul, Porto Alegre (RS), Brazil.
Este item recebeu

Under a Creative Commons license
Informação do artigo
Texto Completo
Bibliografia
Baixar PDF
Estatísticas
Figuras (1)
Tabelas (1)
Table 1. General characterization of subjects
Texto Completo

Dear Editor,

Contact dermatitis (CD) is one of the most common diseases seen in dermatological practice. It represents the majority of occupational dermatoses and produces a considerable socioeconomic impact, especially in industrialized countries.1 CD is caused by external agents that trigger inflammatory reactions through multiple mechanisms when they come into contact with the skin. Patch tests are considered the gold-standard complementary exam for the diagnosis of CD.

Data from the literature suggest that 1-5.4% of the population is sensitized to some cosmetic substance, with about 80% of cases occurring among female patients aged between 20 and 60 years.2 Despite the growing number of cases of CD, Brazilian etiological and epidemiological data are scarce.

The present study - approved by the Ethics Committee of The Federal University of Health Sciences of Porto Alegre (Porto Alegre - RS, Brazil) - evaluated a prospective sample of patients that attended the Dermatology Service at that University aiming to determine the prevalence of allergic CD due to cosmetics and, thus, reveal its etiological profile and associated factors. This cross-sectional study included 28 patients with suspected cosmetic-induced CD (January-October 2016) that agreed with the terms and conditions of the study. Three batteries approved by the Brazilian Society of Dermatology were applied: the Brazilian standard battery, the cosmetic battery, and the hair cosmetic battery (IPI ASACPHARMA®). The results were analyzed according to the criteria of the International Dermatitis Research Group.

The statistical analysis of the data was performed using the SPSS-23 software; chi-squared tests with a significance level of 95% (p < 0.05) were used. Females predominated (92.9%) and the median age was 51 years; 43% tested positive for the standard battery, 29% for the cosmetic battery and 11% for the hair cosmetic battery, where nickel (29%), coconut diethanolamine (63%), and decyl glucoside (34%) were, respectively, the most frequent agents in each battery. A total of 89.3% of the tests were considered relevant and the lesions were most frequently located on the head and neck (57.1%). Clinical improvement within 30 days of the removal of allergens was reported by 92.9% of the patients. Angry back syndrome was observed in three patients (10.7%) and patients over 50 years of age were positive in 59.1% of the tests. No significant association was found between history of atopy and testing positive (p <0,610).

Table 1 and graph 1 present the data from the present research and compares them with those found in the literature, thus the following considerations can be made: previous studies found the face to be the region most frequently affected by cosmetic-induced CD, while the present study found a greater frequency in the head and neck. The components of fragrances and preservatives are the most frequent contact cosmetic allergens.3

Table 1.

General characterization of subjects

AGE  Up to 50 years: 12 (42,9%) 50 years or more: 16 (57,1%)  Extra-Work Activities  Yes: 10 (35,7%) No: 18 (64,35) 
SEX  Male: 2 (7,1%) Female: 26 (92,9%)  USE OF INDIVIDUAL PROTECTION EQUIPMENT  Yes: 4 (14,3%) No: 28 (24%) 
PHOTOTYPE  I: 0 (0%) I: 4 (14,3%) III: 14 (50%) IV: 6 (21,45) V: 3 (10,7%) VI: 1 (3,6%)  HAND HYGIENE  Water and soap: 23 (82,1%) Alcohol: 1 (3,6%) Water: 4 (14%) 
RACE  White: 16 (57,1%) Brown: 5 (17,9%) Black:7 (25%)  EVOLUTION OF DERMATITIS  6 months or less: 4 (14%) 6-12 months: 7 (25%) Over 12 months: 17 (60,7%) 
SCHOOLING  Primary: 9 (32,1%) Secundary: 10 (35,7%) Higher education: 6 (21,7%) No schooling: 3 (10,7%)  TREATMENT CHOICE  Topical: 5 (17,9%) Systemic: 7 (25%) Both: 6 (21,4%) No treatment: 10 (35,7%) 
COMORBIDITIES  Present: 24 (85,7%) Absent: 4(14,3%)  LOCATION OF PREVIOUS LESION  Head and neck: 23 (82,1%) Trunk: 9 (32,1%) Limbs: 17 (60,7%) 
ALCOHOL COMSUPTION  Yes: 6 (21,5%) No: 22 (78,6%)  LOCATION OF CURRENT LESION  Head and neck: 16 (57,1%) Trunk: 4 (14,3%) Limbs: 15 (61,3%) 
SMOKING  Smokers: 2 (7,1%) Non-Smokers: 26 (92,9%)  PREVIOUS ATOPY  Personal: 5 (17,9%) Family: 3 (10,7%) Personal and family: 14 (50%) No atopy: 6 (21,4%) 
Graph 1.

Positive agents (96 hours). Agents that tested positive after 96 hours in the standard battery (A), cosmetic battery (B), and hair cosmetic battery (C)

(0.05MB).

While in the United Kingdom 23% of women and 18,8% of men experienced adverse reactions to a personal care product; in this study, considering all allergens tested, 13 (46%) patients effectively experienced an allergic reaction to some cosmetic component and 11 (39%) had a positive reaction to more than one agent in all three batteries. 4

The most common allergens were nickel, kathon (methylisothiazoline), and cobalt in the standard battery; coconut diethanolamine, amerchol L101, and tosilamide resin in the cosmetic battery; and decylglucoside 5%, lauryl polyglucose, and P-aminophenol in the hair cosmetic battery. An earlier study showed that nickel presented a higher prevalence of sensitization when isolated than other metals and was the main sensitizer in women.3

Kathon, which is used as a cosmetic marker, is considered one of the major clinical causes of allergic dermatitis. A study carried out in São Paulo, Brazil, found that 46% of tests were positive for cosmetics and the main causative agents were butylated hydroxytoluene (BHT) and triethanolamine (causing 19,18% of cases each), followed by ammonium thioglycolate (17,81%), sorbic acid (12,33%), tosylamide (10,95%), and germall (8,22%). 5 In the hair cosmetic battery, we found a lower prevalence of allergies but there are no studies to establish a comparison.

More studies focusing on the prevalence of CD to cosmetics (including its components) in different regions of Brazil are necessary given their frequent use. Multicentric studies with standardized methodologies and larger patient samples should be encouraged so that the main sensitizing agents and their allergenic potential can be identified and reported. □

Acknowledgements

We would like to thank all patients that participated in the study, the IPI ASACPHARMA company for donating the contact test batteries, and to the UFCSPA Dermatology Service (resident medical colleagues, academics, preceptors and employees).

References
[1.]
Martins LE, Reis VM..
Immunopathology of allergic contact dermatitis..
An Bras Dermatol., 86 (2011), pp. 419-433
[2.]
Kumar P, Paulose R..
Patch testing suspected allergic contact dermatitis to cosmetics..
Dermatol Res Pract., 2014 (2014), pp. 695387
[3.]
Duarte I, Lazzarini R, Buense R, Pires MC..
Contact dermatitis..
An Bras Dermatol., 75 (2000), pp. 529-548
[4.]
González-Munoz R, Conde-Salazar L, Vanó-Galván S..
Dermatitis alérgica de contacto a cosméticos..
Actas Dermosifiliogr., 105 (2014), pp. 822-832
[5.]
Silva EA, Bosco MR, Mozer E..
Study of frequency of allergens in cosmetics components in patients with suspected allergic contact dermatitis..
An Bras Dermatol., 87 (2012), pp. 263-268

Work conducted at the Universidade Federal de Ciências da Saúde de Porto Alegre, Porto Alegre (RS), Brazil.

Copyright © 2019. Anais Brasileiros de Dermatologia
Baixar PDF
Idiomas
Anais Brasileiros de Dermatologia (Portuguese)
Opções de artigo
Ferramentas
en pt
Cookies policy Política de cookies
To improve our services and products, we use "cookies" (own or third parties authorized) to show advertising related to client preferences through the analyses of navigation customer behavior. Continuing navigation will be considered as acceptance of this use. You can change the settings or obtain more information by clicking here. Utilizamos cookies próprios e de terceiros para melhorar nossos serviços e mostrar publicidade relacionada às suas preferências, analisando seus hábitos de navegação. Se continuar a navegar, consideramos que aceita o seu uso. Você pode alterar a configuração ou obter mais informações aqui.